Product recommendation | Dedicated electrochemical oxygen sensor for medical field

Medical oxygen is the most widely used medical gas in hospitals. It is widely used clinically. It is mainly used for shock treatment caused by factors such as drowning, nitrous acid, cocaine, carbon monoxide, and respiratory muscle paralysis. It is also used for the prevention work of pneumonia, myocarditis, emphysema, and myocardial dysfunction.

Apr 07,2023


Medical oxygen is the most widely used medical gas in hospitals. It is widely used clinically. It is mainly used for shock treatment caused by factors such as drowning, nitrous acid, cocaine, carbon monoxide, and respiratory muscle paralysis. It is also used for the prevention work of pneumonia, myocarditis, emphysema, and myocardial dysfunction.

Oxygen concentration alarm is the alarming phenomenon with the highest probability of occurrence in clinical use. At present, the monitoring of oxygen concentration mostly adopts the oxygen sensor of the electrochemical principle.

How an electrochemical oxygen sensor works

Oxygen undergoes a reduction reaction on the working electrode, and an oxidation reaction on the anode material, and releases charges to form a current. The magnitude of the generated current is proportional to the partial pressure of oxygen and follows Faraday's law. The magnitude of the partial pressure of oxygen can be determined by testing the magnitude of the current.

Compared with industrial oxygen sensors, medical equipment has strict requirements for oxygen sensors, and the technical threshold is high. Many domestic sensor manufacturers cannot meet the relevant requirements. The MED-O2-LA oxygen sensor independently developed and produced by Winsen Technology has excellent performance, low power consumption, high precision, wide linear range, excellent repeatability, stability, etc. It is suitable for oxygen monitoring in oxygen generator control devices and medical equipment such as breathing and anesthesia in the medical industry.

Electrochemical Oxygen Sensor MED-O2-LA

   Technical Parameters

Project

Parameter

Detection gas

Oxygen (O2)

Measure Range

0-100% O2

Sensitivity

8-15mV (in the air)

T90

<15s

Repeatability

< 2%( output value)

Output linearity

full scale linearity

Interface

P/N 5520257-2

Temperature range

-20℃~50℃

Humidity range

0%~99%RH non-condensing

Pressure range

0.5 Bar-2.0 Bar

Service life

1.5x106%O2 hours (20°C)
0.8x106%O2 hours (40°C)

 

MED-O2-LA provides an adapter that can be installed on the sensor thread to allow the gas to enter the sensor directly for reaction.

Electrochemical gas sensors are a proven technology with linear output, low power consumption, repeatability, and high accuracy, and have been widely used in medical, industrial, and other markets.

Depending on the application industry, the demand for electrochemical gas sensors with better performance is also stronger. Winsen Technology has been deeply involved in the field of sensors for more than 20 years. The electrochemical series products include ME2, ME3, ME4, MEu, MED, and other types, which are suitable for flammable and explosive gases, toxic gases, oxygen monitors, etc., which are in civil, industrial, medical, and other fields.

 