Home Combustible Gas Alarm

The combustible gas alarm is an alarm device for detecting gas leakage. The component that reacts to the combustible gas is a gas sensor, and the response signal is converted into an electrical signal through the circuit board. When the combustible gas in the air reaches a certain concentration value, the alarm will alarm. The high-end household combustible gas alarm can automatically start the exhaust equipment and close the gas pipeline valve at the same time. A wireless transmission device can be installed inside the gas alarm to realize overall monitoring and network alarm to ensure the safety of everyone's life and property.

There are two hazards of gas leakage: one is leakage, combustion and explosion, and the other is personnel inhalation poisoning; among the two hazards,the prevention of combustion and explosion is the top priority.

Health is as important as safety

Traditional home combustible gas alarms only sound on-site when there is a serious gas leakage, but in fact, or carbon monoxide concentrations exceeding the standard caused by gas leakage or incomplete combustion often occur.Although this situation does not cause the same danger as an explosion, it can seriously endanger our health over many years.

ME2-CO CO Sensor combustible gas sensor

ME2-CO CO Sensor

Winsen ME2-CO electrochemical sensor can accurately analyze the concentration of colorless and odorless combustible gas and carbon monoxide. When the gas concentration is abnormal, the sensor will immediately give a response signal,

which greatly improves the user's vigilance and prevents problems before they occur. Carbon monoxide is a colorless, odorless, non-irritating gas that cannot be sensed by human. The maximum concentration that a healthy adult can bear within eight hours is 50ppm. When the concentration is 800ppm, dizziness, nausea, and spasm within 45 minutes, loss of consciousness within 2 hours, death within 2-3 hours. Winsen electrochemical sensor detects the concentration of carbon monoxide between 0-1000ppm, and the maximum measurement limit can reach 2000ppm. It can effectively and timely feedback concentration data, prevent carbon monoxide poisoning, and protect health and safety.

The combustible gas sources in people's lives are roughly divided into: liquefied gas (LPG),natural gas,coal gas (LPG) and other alkane combustible gases, etc.

The current gas detection methods for the combustible gas industry are:

Home combustible gas is mainly detected by semiconductor and planar semiconductor components. At present, domestic products occupy the mainstream market, mainly measuring 0-10000ppm. Municipal gas companies mainly use catalytic components, mainly measuring 100% LEL. Mainly used for gas storage, transportation, pipeline safety inspection and other places. After 2007, high-end gas detection products in the gas industry have gradually adopted infrared gas sensors, which can measure 100% LEL and 100% VOL.At the same time, the laser beam technology is used in the gas industry, especially in the long-distance inspection.

Home Combustible Gas Alarm

Liquefied Petroleum Gas (LPG)

MQ-5 propane sensor for detecting LPG

MQ-5 propane sensor
for detecting LPG

The main components are ethylene, ethane, propylene, propane and butane, etc., which are liquid in the gas cylinder. Once they flow out, they will vaporize into a flammable gas that is about 250 times the original volume. It is easy to spread and will burn or explode when encountering flame. If this kind of liquefied gas is used, it is necessary to select an alarm equipped with a propane sensor in a targeted manner.

Home Combustible Gas Alarm

Natural gas

Natural gas sensorNatural gas is an important energy source and is widely used as city gas and industrial fuel.

Home Combustible Gas Alarm

MP-4 methane sensor for detecting natural gas

MP-4 methane sensor for
detecting natural gas

Natural gas is one of the safer gas. It does not contain carbon monoxide and is lighter than air. Once it leaks, it will spread upward immediately, and it is not easy to accumulate to form an explosive gas, so it is safer. The main component of natural gas is methane, which is generally transported by pipelines. Therefore, for safety, most cities now use natural gas for supply. When using natural gas, it is necessary to select an alarm equipped with a methane sensor detection module.

Home Combustible Gas Alarm

Coal gas

Coal gas sensorAlthough artificial coal gas (coking gas) is currently used less, it is still used in some areas.It is necessary to select a hydrogen sensor if use coal gas.

Coal gas is made by dry distillation or vaporization of solid raw materials such as coal or coke, and its main components are carbon monoxide, methane and hydrogen. The working pressure of coal-made gas is 1.0KPa, and the gas supply method is generally pipeline.

Home Combustible Gas Alarm

MQ-8 sensor for hydrogen detection

MQ-8 sensor for
hydrogen detection

Winsen Technology is suitable for the detection of combustible gas such as liquefied gas, natural gas,coal gas, etc. After years of development, gas sensor technology has become very mature. Sensors and modules such as MP series planar semiconductor gas sensors, MC100 series carrier catalytic gas sensors, and MQ series semiconductor gas sensors are widely used in household gas leak detection.

Attached table: sensor selection of gas detection in combustible gas industry

Name

Model Test object Measurement range Picture
Semiconductor sensor MQ series(MQ-2、MQ-4、MQ-5、MQ-6 etc.) Various combustible gases 300-1000ppm MQ series sensor(MQ-2、MQ-4、MQ-5、MQ-6 etc.)
Planar Gas Sensor MP series(MP-4、MP-5) Various combustible gases 300-10000ppm MP series sensor (MP-4、MP-5)
Catalytic gas sensor MC series(MC101、MC102、MC105 etc.) Various combustible gases 0-100%LEL MC series sensor(MC101、MC102、MC105 etc.)
Catalytic gas sensor MC series(MC112、MC113、MC114) Various combustible gases 0-100%LEL MC112、MC113、MC114 sensor
Thermally Conductive Gas Sensors MD series(MD61) Various combustible gases 0-100%VOL MD61 sensor
Infrared Gas Sensor MH4 series(MH-440D) Various combustible gases 0-100%VOL
optional
MH-440D
Infrared Gas Sensor MH7 series(MH-741) Various combustible gases 0-100%VOL
optional
MH-741
Fire fighting

RELATED PRODUCTS

Electrochemical CO Sensor MEu-2CO


The MEu-2CO sensor is a fuel cell sensor. Carbon monoxide and oxygen undergo a corresponding oxidation-reduction reaction on the working electrode and counter electrode and release charges to form a current. The current generated is proportional to the concentration of carbon monoxide and follows Faraday's law. The size can determine the concentration of carbon monoxide.

Learn More

Electrochemical CO Sensor ME2-CO-Ф14×14


Carbon monoxide sensor ME2-CO-Ф14×14 is a fuel cell sensor. Carbon monoxide and oxygen undergo a corresponding oxidation-reduction reaction on the working electrode and the counter electrode and release charges to form a current. The magnitude of the generated current is proportional to the concentration of carbon monoxide and follows Faraday's law. The level of carbon monoxide concentration can be determined by measuring the magnitude of the current.

Learn More

Electrochemical CO Sensor ME2-CO


ME2-CO electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current.

Learn More

Semiconductor H2 Sensor MQ-8


Sensitive material of MQ-8 gas sensor is SnO2, which with lower conductivity in clean air. When hydrogen gas exists, the sensor’s conductivity gets higher along with the gas concentration rising. Users can convert the change of conductivity to correspond output signal of gas concentration through a simple circuit. MQ-8 gas sensor has high sensitivity to hydrogen gas, also has anti-interference to other gases. This sensor can detect hydrogen, especially city gas. It is a kind of low-cost sensor for kinds of applications.

Learn More

Semiconductor Combustible Gas Sensor MQ-5


Sensitive material of MQ-5 gas sensor is SnO2, which with lower conductivity in clean air. When the target flammable gas exist, the sensor' s conductivity gets higher along with the gas concentration rising. Users can convert the change of conductivity to correspond output signal of gas concentration through a simple circuit. MQ-5 gas sensor has high sensitivity to butane, propane, methane and can detect methane and propane at the same time. It also can detect kinds of flammable gases, especially LPG(propane). It is a kind of low–cost sensor for many applications.

Learn More

Flat Semiconductor Methane MP-4 Sensor


MP-4 model with advanced planar construction is comprised of heater and metal oxide semiconductor material of subminiature Al2O3 ceramic plate, fetch out electrode down-lead, encapsulation in metal base and cap. When the target gas exists, the sensor’s conductivity is more higher along with the gas concentration rising. Please use simple electrocircuit, convert change of conductivity to correspond output signal of gas concentration.

Learn More

How to choose the right sensor for your project?

We have 17 sensor series, 200+ categories, and 300+ detection objects for gas detection. Such as CO, CO2, VOC, PM2.5, CH4, LPG and so on. In particular, we also have MEMS sensors. According to your industry application, gas principle, power consumption, accuracy, and range requirements, and we can select a specific model for you. You can also use the product filter below to choose a suitable product, or choose online serivce.

Still need help? Join the community

Related Links

Support

The first six FAQs. Use the search bar above to reveal more!

Can the Two Voltages of Mq-7 Exist All the Time, or Do They Need to Be Powered Alternately? if It is an Alternate Power Supply, What is the Appropriate Power Supply Time?

It requires alternate power supply. Please check the information on the product manual. This sensor is powered by 1.5V and 5V alternately. The low temperature and low voltage (1.5V) state can detect CO, and the high voltage (5V) is the desorption process. The recommended 5V voltage duration is 60s, 1.5V voltage duration is 90s to alternately supply power. Since it is a desorption process at 5V, it is normal for the voltage to drop when CO is 150ppm.

What is the Difference Between Semiconductor Sensors and Electrochemical Sensors?

There is no good linear correspondence between the gas concentration and voltage of the semiconductor sensor, and it is generally only used for fixed-point calibration products; there is a good linear correspondence between the gas concentration and the output current of the electrochemical sensor, and can be made into quantitative detection products.

What Are the Precautions for Manual Soldering of Semiconductor Sensors?

1. Flux: rosin flux with the least chlorine; 2. Constant temperature soldering iron; 3. Temperature: 250℃; 4. Time: no more than 3 seconds.
SUBMIT
Security verification
%{tishi_zhanwei}%