Chinese CO2 Sensor Manufacturer

Winsen is a set of CO2 sensor research and development, production, sales and application solutions as one of the high-tech enterprises.

Over 20 years of manufacturing experience

ISO9001 approved factory

CE and UL certificates are available

Meet customization requirements

Send Inquiry Now

Winsen CO2 Sensor

Winsen can provide CO2 sensors for smart homes, schools, agriculture, air quality monitoring equipment, fresh air systems, automotive air conditioning systems, air purifiers, etc.

Our independent research and development of CO2 sensor has been more than 20 years of market validation, with low power consumption, small size, long service life and other characteristics.

In addition, we offer you a variety of different materials, such as gold-plated, aluminum-plated, etc. And there are plug pin, no plug pin, with bottom plate and other versions are optional.

According to customer needs, Winsen customizes corresponding solutions.

Advantages of CO2 sensor

High Sensitivity

High Sensitivity

Short response time, detect CO2 gas quickly and accurately

Output Signal

Output Signal

UART, analog voltage signal, PWM waveform, etc.

Long Life

Long Life

More than 5 years, less affected by changes in temperature and humidity

Wide Application

Wide Application

Schools, agricultural, automobiles, air quality monitoring, etc.

Principle of infrared CO2 sensor

Different gases have their own unique infrared absorption spectral bands, and the absorption intensity of gas to infrared light is related to its concentration. The higher the concentration, the stronger the absorption of infrared light by the gas.

Infrared CO2 sensor is a gas sensing device that selects absorption characteristics based on the near-infrared spectrum of different gas molecules, identifies gas classification and determines its concentration according to the relationship between gas concentration and absorption intensity (Lambert-Beer law).

Send Inquiry Now
Principle of infrared CO2 sensor

CO2 sensor application scenarios

CO2 sensor application scenarios

CO2 sensors can play their role in all walks of life. Through more than 20 years of continuous accumulation and cooperation with customers in different industries, Winsen can help you meet the needs of different scenarios.

HVAC equipment

Air Quality Monitoring Equipment

Air purification equipment

School, university

Agriculture, mining

Send Inquiry Now

CO2 sensor integration module

The proposal of the "dual carbon goal" has brought more and more attention to carbon dioxide emissions. Winsen focuses on helping customers solve different application problems. Our CO2 sensors can be integrated with other sensors in an all-in-one module to meet customized solutions in special cases.

If you have any needs, please let us know and we will do our best to help you.

Send Inquiry Now
CO2 sensor integration module

How Winsen guarantees the quality of CO2 sensors

Winsen has more than 100 R&D personnel and more than 500 sets of production and R&D equipment. Many R&D achievements have passed the appraisal of scientific and technological achievements in Henan Province and reached the international advanced level. At present, Winsen has more than 100 invention and utility model patents, more than 10 software copyrights, and has led or participated in the formulation of 14 national and industry standards.

Winsen CO2 sensor has a wide measurement range, wide detection range, simple application, not easy to be poisoned, and has a lot of options.

In addition, the Winsen CO2 sensor will be aged, calibrated, tested and packaged before delivery from the factory, and then transferred to the warehouse for delivery. If the sensors are placed in the warehouse for more than 7 days, we will calibrate and test them again to ensure the quality of the product. When calibrating, we will first calibrate the temperature (8 temperature points), and then calibrate the gas (zero point and SPAN point), and the SPAN point is determined by the customer's demand range.

We can provide you with professional advice in different industries.

Click on the Consulting

Winsen,Create Value for Customers

7

7 sensor series

200 +

200+ categories

300 +

300+ indicator detection

From NL N***n

From NL N***n

Works great and I trust it's accuracy.

25 Mar,2022

From RU V***o

From RU V***o

Item as described. Good seller. Nice to deal with.

18 Mar,2022

From US R***r

From US R***r

Works as replacement for sensor used in Invisiclean Claro. Shipped quickly and was well packaged.

22 Jul,2022

From PS ن***ر

From PS ن***ر

Simple to use and it helped me.

07 Jul,2022

Related Products

CO2 Sensor Guide

We have summarized the following questions to help you make better choices.

Question

What is a CO2 sensor?


Answer

The CO2 sensor is a device that converts the collected information (CO2 concentration) into signals (such as electrical signals, acoustic signals, light signals, digital signals, etc.) that are more easily recognized by humans.

Question

What are the range of infrared CO2 sensor?


Answer

The range of infrared CO2 sensor is 0-2000ppm, 0-5000ppm, 0-1%VOL, 0-3%VOL, 0-5%VOL, 0-10%VOL, 0-15%VOL. Different models of sensors have different ranges, you can choose the appropriate model according to the actual use environment, or contact us for help.

Question

What should be paid attention to when CO2 sensors are used in agricultural greenhouses?


Answer

Agricultural greenhouses are a special application scenario. The respiration of plants is to absorb CO2 by exhaling oxygen, so the CO2 concentration may be lower than 400ppm. At this time, the co2 sensor needs to turn off the automatic calibration function.

Question

What calibration methods are available for CO2 sensors?


Answer

For the convenience of customers, the CO2 sensor has three calibration methods to choose from: manual zero calibration, automatic zero calibration and command zero calibration. The zero point calibration function refers to the calibration of 400ppm.

1. Manual zero calibration. Manual zero calibration is to input the HD pin of the sensor to a low level (0V) for zero calibration, and the low level needs to last for more than 7 seconds. Before zero calibration, it is necessary to ensure that the sensor operates stably for more than 30 minutes at a concentration of 400ppm.

2. Automatic zero calibration. The automatic zero-point calibration function means that after the sensor runs continuously for a period of time, it intelligently judges the zero point according to the environmental concentration and calibrates itself. The calibration cycle is an automatic calibration every 24 hours since the power-on operation. The zero point for automatic

calibration is 400ppm. The automatic zero calibration function is suitable for office environment and home environment. However, it is not suitable for agricultural greenhouses, farms, cold storages and other places. In such places, the automatic zero calibration function should be turned off. After closing, the user should periodically calibrate the sensor zero point.

3. Command zero calibration. Sending calibration commands to the sensor through the serial port (URAT) can realize sensor zero calibration. For the zero point calibration command, please refer to the product manual.

Question

Precautions for using CO2 sensor


Answer

● During the welding, installation and use of CO2 sensor, the plastic gold-plated cavity should be prevented from being subjected to pressure in any direction.

● If CO2 sensor needs to be placed in a small space, the space should be well ventilated, especially the diffuser window should be in a well ventilated location.

● In order to ensure that the CO2 sensor can work normally, the power supply voltage must be kept in the range of (5.0±0.1) V DC, and the power supply current must not be less ● than 150mA. If it is not within this range, the sensor may malfunction, the output concentration of the sensor is too low, or the sensor cannot work normally.

● CO2 sensor should be kept away from heat sources and protected from direct sunlight or other thermal radiation.

● CO2 sensor should be calibrated regularly, and the calibration period is recommended not to exceed 6 months.

● Do not use CO2 sensor for a long time in an environment with high dust density.

● When manually calibrating the zero point or sending a command to calibrate the zero point, it must work continuously for more than 30 minutes in a stable gas environment (400ppm).

● CO2 sensor is prohibited from using wave soldering.

● When soldering with a soldering iron, the temperature must be set at (350±5) °C, and the soldering time must be less than 3 seconds.

Welcome to contact us

Security verification
SUBMIT
CO2 sensor price
SUBMIT
Security verification
%{tishi_zhanwei}%